Matrix Converterのメーカーや取扱い企業、製品情報、参考価格、ランキングをまとめています。
イプロスは、 製造業 BtoB における情報を集めた国内最大級の技術データベースサイトです。

Matrix Converter - メーカー・企業と業務用製品 | イプロスものづくり

Matrix Converterの製品一覧

1~11 件を表示 / 全 11 件

表示件数

75kW matrix converter

Expanding into the large-capacity market in the future based on the 75kW matrix converter!

We would like to introduce the "75kW Matrix Converter" that we handle. The load of the inverter panel equipped with the 75kW matrix converter is a three-phase induction motor (75kW) plus a limit load fan. Main features include instantaneous overcurrent protection, overload protection, input voltage overvoltage protection, input voltage undervoltage protection, overheating protection, and motor internal heating protection via a PTC thermistor input circuit. 【Specifications (partial)】 ■ Applicable motor capacity: 75kW ■ Rated current: 264A ■ Overload current rating (the percentage values are ratios to the rated output current of the inverter) ・120% for 60 seconds, 150% for 3 seconds ■ Rated voltage: 3-phase 200V ■ Output frequency: 10–200Hz *For more details, please download the PDF or feel free to contact us.

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Matrix Converter <Development Achievements>

Applicable to various applications! Particularly effective for markets using large-capacity three-phase AC motors.

We would like to introduce our company's development achievements in "Matrix Converters." We have developed a product with an input/output voltage rating of 3-phase 200V, an output motor capacity of 7.5kW, and a size of 260mm × 200mm (approximately the size of B5 paper). Matrix converter technology is expected to be applied not only in motor drives but also particularly in electric vehicles, represented by rapid chargers. Please feel free to contact us when needed. 【Development Achievements】 ■ Input/Output Voltage Rating: 3-phase 200V ■ Output: Motor Capacity 7.5kW ■ Size: 260mm × 200mm (approximately the size of B5 paper) *For more details, please download the PDF or feel free to contact us.

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Proposal for HVAC

No equipment is needed for power supply harmonic countermeasures! Proposal for the Matrix Converter "VAC Series."

"HVAC" achieves miniaturization by eliminating the need for peripheral devices through harmonic suppression. Additionally, it allows for a reduction in generator capacity, leading to lower initial investment, and contributes to energy savings through the high-efficiency operation of PM motors. Due to its simple design, wiring labor can be significantly reduced, complicated calculations are unnecessary, and application procedures can be easily completed. [Features] - Miniaturization of control panels - Miniaturization of power supply equipment capacity due to high power factor - Miniaturization of emergency generators due to power supply harmonic suppression - Energy savings - Simple design *For more details, please refer to the PDF materials or feel free to contact us.*

  • converter
  • Matrix Converter

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Matrix Converter

Energy loss is reduced because power conversion is completed in one step! More energy-efficient than inverter systems.

Let me introduce you to the "Matrix Converter." An inverter converts alternating current (AC) power input from an external AC power source into direct current (DC) power, and then further converts it into suitable alternating current (AC) power for output. As a result, energy loss due to power conversion occurs twice. On the other hand, a matrix converter can directly convert the input alternating current power into suitable alternating current power for each electrical device. Therefore, energy loss due to power conversion occurs only once, improving power conversion efficiency. 【Features】 ■ Directly converts alternating current power into suitable alternating current power for each electrical device ■ Energy loss due to power conversion occurs only once ■ Improved power conversion efficiency *For more details, please download the PDF or feel free to contact us.

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Matrix Converter <Advantages>

No need for large reactors or high-capacity electrolytic capacitors, enabling cost reduction and miniaturization!

Here are the benefits of the "Matrix Converter." It has a high power factor (above 0.98), theoretically reaching 1.0 (with reactive power = 0). This offers advantages such as reduced equipment capacity due to efficient use of equipment and lower electricity costs (basic fees). Additionally, since there is no need to install harmonic suppression devices (AC reactors, DC reactors, harmonic suppression equipment), installation costs and power losses after installation can be minimized. [Features] - Reduction of equipment capacity due to efficient use - Lower electricity costs (basic fees) - No need for installation of harmonic suppression devices *For more details, please download the PDF or feel free to contact us.

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Practical Matrix Converter Technology Equipment Expansion

Break the vicious cycle of equipment expansion at its root and improve investment efficiency! Accelerate factory production expansion.

Our "Practical Matrix Converter Technology" breaks the vicious cycle of adding harmonic countermeasures every time equipment is expanded. With a design that eliminates the need for harmonic countermeasures, you are completely freed from the cycle of adding measures with each equipment expansion. This reduces installation space and investment costs. By eliminating the costs of harmonic countermeasures, the investment efficiency in production equipment dramatically improves. This shortens the payback period and frees you from unnecessary cost increases. 【Features】 ■ 75kW practical track record ■ Power factor of 0.98 or higher (measured value) ■ No need for high-frequency countermeasures ■ Compact and lightweight design *For more details, please download the PDF or feel free to contact us.

  • converter
  • Other factory equipment
  • Matrix Converter

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

【実用型マトリクスコンバータ技術】電力料金高騰

独自の実用化技術により高力率・高効率を実現し、電力基本料金を削減!

当社の「実用型マトリクスコンバータ技術」は、電力基本料金の高騰による 企業収益圧迫を断ち切ります。 高力率・高効率なクリーンな電源供給により、生産設備で深刻化する 電力基本料金問題から完全に解放。企業収益改善を後押しします。 電力基本料金を根本から削減できることで、力率改善設備への大規模更新 工事が不要に。限られた設備投資予算を最大限に活用し、生産性向上を 加速させます。 【特長】 ■75kW実用実績 ■力率0.98以上(実測値) ■高周波対策不要 ■小型・軽量設計 ※詳しくはPDFをダウンロードしていただくか、お気軽にお問い合わせください。

  • converter
  • Other Energy Saving
  • Matrix Converter

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Practical Matrix Converter Technology for Air Conditioning and Ventilation Equipment

Achieve large capacity with energy saving and reduction of electricity costs! Accelerating energy efficiency in air conditioning and ventilation equipment.

Our "Practical Matrix Converter Technology" solves the serious issues of increasing electricity costs and the need for equipment updates due to the growing energy-saving demands in air conditioning and ventilation systems. To address the harmonics generated by inverters, large passive filters and other countermeasures are essential, leading to wasted installation space and costs. Our technology overcomes these challenges. Additionally, there is no need for separate harmonic countermeasure equipment, significantly reducing installation space and costs. 【Features】 ■ 75kW practical performance ■ Power factor of 0.98 or higher (measured value) ■ No need for high-frequency countermeasures ■ Compact and lightweight design *For more details, please download the PDF or feel free to contact us.

  • converter
  • air conditioning
  • Matrix Converter

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

【実用型マトリクスコンバータ技術】工作機械の高精度化

独自の実用化技術により高調波を大幅に抑制し、クリーンな電源を供給!

当社の「実用型マトリクスコンバータ技術」は、工作機械の高精度化で 電源ノイズが深刻化するという悪循環を断ち切ります。 ノイズ対策設備不要で盤サイズを削減し、電源ノイズ問題を断ち切り 高精度加工を加速。 高精度化と電源ノイズの悪循環や、ノイズ対策設備による盤の巨大化 といった課題を解決します。 【特長】 ■75kW実用実績 ■力率0.98以上(実測値) ■高周波対策不要 ■小型・軽量設計 ※詳しくはPDFをダウンロードしていただくか、お気軽にお問い合わせください。

  • converter
  • Other machine tools
  • Matrix Converter

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Practical Matrix Converter Technology for Large Capacity Devices

Achieving compact and lightweight design even with large capacity! Reducing panel size without the need for harmonic measures.

Our "Practical Matrix Converter Technology" breaks the vicious cycle where the installation size of large-capacity equipment exceeds installation constraints. In production sites where large capacity is advancing, the benefits of no need for harmonic measures and compact lightweight design are particularly significant. This allows for the acceleration of the introduction of necessary large-capacity equipment without worrying about installation constraints. Additionally, by eliminating the need for conventional harmonic mitigation equipment, we can significantly reduce the size of the control panel. This maximizes the limited space in factories and improves production efficiency. 【Features】 ■ 75kW practical performance ■ Power factor of 0.98 or higher (measured value) ■ No need for high-frequency measures ■ Compact and lightweight design *For more details, please download the PDF or feel free to contact us.

  • converter
  • Other factory equipment
  • Matrix Converter

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

【実用型マトリクスコンバータ技術】物流センター

独自の実用化技術により大容量で電源設備肥大化を抑制!物流センター自動化を加速

当社の「実用型マトリクスコンバータ技術」は、物流センターの自動化 加速に伴う電源設備大型化の深刻な問題を解決します。 高力率で高調波対策が不要なため、既存受電設備を有効活用でき、 電源設備の肥大化を根本から解決。設置スペースと投資コストを削減します。 力率0.98以上(実測)により、既存の受電設備への負担を軽減し、デマンド 契約電力の最適化が可能。不要な設備増強から解放されます。 【特長】 ■75kW実用実績 ■力率0.98以上(実測値) ■高周波対策不要 ■小型・軽量設計 ※詳しくはPDFをダウンロードしていただくか、お気軽にお問い合わせください。

  • converter
  • Other transportation equipment maintenance and consumables
  • Matrix Converter

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録